home » technical
guide »
doorset leaves & facings »

All Leaderflush Shapland door leaves are designed to meet
specific performance levels as tested – notably compliance
with requirements for BWF-CERTIFIRE certified, fire-rated
doorsets – and are manufactured to exacting standards
which exceed the guidance offered by BS 8214. Selection of
materials and construction methods have been developed with many
years experience to best achieve specified performance, while
adhering to our environmental policy, appropriate standards and
regulations. Core construction is simply determined by us from
the combination of performance requirements selected from the
product range brochures. However, door leaf designations are
summarised below with relevant performance characteristics, for
background information.
| Leaf Designation |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
| ARMADOR 1 NR/30 |
56 |
61 |
 |
 |
NR/FD30 |
 |
33 (4) |
1.80 |
Severe Duty |
|
|
G1 |
Level 2 |
| ARMADOR 1 60 |
56 |
63 |
 |
 |
FD60 |
 |
33 (4) |
1.80 |
Severe Duty |
|
|
G1 |
Level 2 |
| ARMADOR 2 NR/30 |
57 |
68 |
 |
 |
NR/FD30 |
 |
33 (4) |
2.20 |
Severe Duty |
|
|
G2 & S86 |
Level 2 |
| ARMADOR 2 60 |
57 |
70 |
 |
 |
FD60 |
 |
33 (4) |
2.20 |
Severe Duty |
|
|
G2 & S86 |
Level 2 |
| ARMADOR 3 |
51 |
80 |
 |
 |
NR |
|
|
2.16 |
Severe Duty |
|
|
R2 |
Level 2 |
| AUDIODOR 30
NR/30 |
43 |
25 |
 |
|
NR/FD30 |
 |
32 |
1.84 |
Severe Duty |
|
|
|
|
| AUDIODOR 32
NR/30 |
45 |
23 |
 |
 |
NR/FD30 |
 |
32 |
1.63 |
Severe Duty |
|
|
|
|
| AUDIODOR 32 60 |
55 |
33 |
 |
|
FD60 |
 |
32 |
1.63 |
Severe Duty |
|
|
|
|
| AUDIODOR 35 60 |
52 |
39 |
 |
|
FD60 |
 |
35 |
1.68 |
Heavy Duty |
|
|
|
|
| AUDIODOR 38 |
44 |
32 |
 |
|
NR/FD30 |
 |
38 |
1.84 |
Heavy Duty |
|
|
|
|
| AUDIODOR 39 60 |
55 |
68 |
 |
|
FD60 |
 |
39 |
1.94 |
Severe Duty |
|
|
|
|
| AUDIODOR 40 |
44 |
32 |
 |
|
NR/FD30 |
 |
40 |
1.84 |
Heavy Duty |
|
|
|
|
| AUDIODOR 44 |
47 |
54 |
 |
|
NR/FD30 |
 |
44 |
1.82 |
Heavy Duty |
|
|
|
|
| AUDIODOR SUPER |
48 |
60 |
 |
|
NR/FD30 |
 |
46-49 |
1.82 |
Heavy Duty |
|
|
|
|
| AV1 NR/30 |
54 |
34 |
 |
 |
NR/FD30 |
 |
29 |
2.31 |
Severe Duty |
|
|
|
Level 1 |
| AV1 60 |
54 |
36 |
 |
|
FD60 |
 |
29 |
2.31 |
Severe Duty |
|
|
|
Level 1 |
| AV2 NR/30 |
55 |
51 |
 |
 |
NR/FD30 |
 |
33 |
2.31 |
Severe Duty |
|
|
|
Level 2 |
| AV2 60 |
55 |
53 |
 |
 |
FD60 |
 |
33 |
2.31 |
Severe Duty |
|
|
|
Level 2 |
| AV3 |
56 |
54 |
 |
 |
NR |
|
|
2.31 |
Severe Duty |
|
|
|
Level 3 |
| AV4 |
51 |
42 |
 |
 |
NR |
|
|
2.37 |
Severe Duty |
|
|
|
Level 3 |
| ENDURACOR NR/30 |
43 |
22 |
 |
|
NR/FD30 |
 |
28 |
1.50 |
Severe Duty |
(6) |
|
|
|
| ENDURACOR 60 |
55 |
33 |
 |
|
FD60 |
 |
29 |
1.36 |
Severe Duty |
|
|
|
|
| LAMCOR NR/30 |
45 |
23 |
 |
 |
NR/FD30 |
 |
29 |
1.63 |
Severe Duty |
(6) |
|
|
|
| LAMCOR 60 |
53 |
29 |
 |
|
FD60 |
 |
29 |
1.68 |
Severe Duty |
|
|
|
|
| LEADLINE AS
(Code 5/7) |
Varies |
55/68 |
 |
|
NR/FD30/FD60 |
 |
39 (5) |
1.94 |
Severe Duty |
|
 |
|
|
| VULCAN 90/120 |
54 |
35 |
 |
|
FD90/FD120 |
 |
31 |
1.92 |
Medium Duty |
|
|
|
|
(1) Fire resistance - NR = Non-rated; FD30 = 30 minutes; FD60 =
60 minutes. (2) Tested to BS DD 171. (3) Tested to BS
5051. (4) Assessment based on Leaderflush Shapland tests.
(5) Code 7 lead. (6) Severe duty with 1 million cycles,
class 8.
BS 8214 recognises the importance of balancing dissimilar door
facings to avoid exaggerated distortions in the door leaf and
this is catered for as part of our service. Choices of door
lippings for each product range are described in product
brochures. For paired leaves, we offer square meeting stiles, as
rebated meeting stiles are not recommended in BS 8214, nor do we
have test evidence to support their use in fire rated
situations.
Example of door facing balancing:

|