All Leaderflush Shapland door leaves are designed to meet specific performance levels as tested – notably compliance with requirements for BWF-CERTIFIRE certified, fire-rated doorsets – and are manufactured to exacting standards which exceed the guidance offered by BS 8214. Selection of materials and construction methods have been developed with many years experience to best achieve specified performance, while adhering to our environmental policy, appropriate standards and regulations. Core construction is simply determined by us from the combination of performance requirements selected from the product range brochures. However, door leaf designations are summarised below with relevant performance characteristics, for background information.

Leaf Designation Thickness (mm) Weight (kg/m2) Internal Quality External Quality Fire Performance (1) Smoke Control Sound Reduction (RwdB) Thermal Insulation (W/m2K) Mechanical Strength (2) Classification of service life X-Ray Performance Ballistic Resistance (3) Delayed Entry Level (4)
ARMADOR 1 NR/30 56 61 tick tick NR/FD30 tick 33 (4) 1.80 Severe Duty     G1 Level 2
ARMADOR 1 60 56 63 tick tick FD60 tick 33 (4) 1.80 Severe Duty     G1 Level 2
ARMADOR 2 NR/30 57 68 tick tick NR/FD30 tick 33 (4) 2.20 Severe Duty     G2 & S86 Level 2
ARMADOR 2 60 57 70 tick tick FD60 tick 33 (4) 2.20 Severe Duty     G2 & S86 Level 2
ARMADOR 3 51 80 tick tick NR     2.16 Severe Duty     R2 Level 2
AUDIODOR 30 NR/30 43 25 tick   NR/FD30 tick 32 1.84 Severe Duty        
AUDIODOR 32 NR/30 45 23 tick tick NR/FD30 tick 32 1.63 Severe Duty        
AUDIODOR 32 60 55 33 tick   FD60 tick 32 1.63 Severe Duty        
AUDIODOR 35 60 52 39 tick   FD60 tick 35 1.68 Heavy Duty        
AUDIODOR 38 44 32 tick   NR/FD30 tick 38 1.84 Heavy Duty        
AUDIODOR 39 60 55 68 tick   FD60 tick 39 1.94 Severe Duty        
AUDIODOR 40 44 32 tick   NR/FD30 tick 40 1.84 Heavy Duty        
AUDIODOR 44 47 54 tick   NR/FD30 tick 44 1.82 Heavy Duty        
AUDIODOR SUPER 48 60 tick   NR/FD30 tick 46-49 1.82 Heavy Duty        
AV1 NR/30 54 34 tick tick NR/FD30 tick 29 2.31 Severe Duty       Level 1
AV1 60 54 36 tick   FD60 tick 29 2.31 Severe Duty       Level 1
AV2 NR/30 55 51 tick tick NR/FD30 tick 33 2.31 Severe Duty       Level 2
AV2 60 55 53 tick tick FD60 tick 33 2.31 Severe Duty       Level 2
AV3 56 54 tick tick NR     2.31 Severe Duty       Level 3
AV4 51 42 tick tick NR     2.37 Severe Duty       Level 3
ENDURACOR NR/30 43 22 tick   NR/FD30 tick 28 1.50 Severe Duty tick(6)      
ENDURACOR 60 55 33 tick   FD60 tick 29 1.36 Severe Duty        
LAMCOR NR/30 45 23 tick tick NR/FD30 tick 29 1.63 Severe Duty tick(6)      
LAMCOR 60 53 29 tick   FD60 tick 29 1.68 Severe Duty        
LEADLINE AS (Code 5/7) Varies 55/68 tick   NR/FD30/FD60 tick 39 (5) 1.94 Severe Duty   tick    
VULCAN 90/120 54 35 tick   FD90/FD120 tick 31 1.92 Medium Duty        

 

(1) Fire resistance - NR = Non-rated; FD30 = 30 minutes; FD60 = 60 minutes.
(2) Tested to BS DD 171.
(3) Tested to BS 5051.
(4) Assessment based on Leaderflush Shapland tests.
(5) Code 7 lead.
(6) Severe duty with 1 million cycles, class 8.

BS 8214 recognises the importance of balancing dissimilar door facings to avoid exaggerated distortions in the door leaf and this is catered for as part of our service. Choices of door lippings for each product range are described in product brochures. For paired leaves, we offer square meeting stiles, as rebated meeting stiles are not recommended in BS 8214, nor do we have test evidence to support their use in fire rated situations.

Example of door facing balancing:

Example of door facing balancing