about us
Leaderflush Shapland

top navigation

Skip top navigation

main navigation

Skip main navigation
 

home »  technical guide »  design considerations: effective clear widths »

design considerations

Effective clear widths

Approved Document M, Diagram, Effective clear width

Effective clear width

Clear opening width’ is measured up to any projecting door item including furniture, weatherboards, etc., as shown above. A space of at least 300mm is generally required next to the leading edge of the door to enable wheelchair users to reach and grip the handle, unless the door is power operated. Door opening furniture should be operable with one hand (e.g. lever action).

.Effective clear width

Approved Document M, Table 2 Minimum Effective Clear Widths

Direction & width of approach :
New buildings
(mm)
Existing buildings
(mm)
Straight-on
(without a turn or
oblique approach)
800
750
At right angles to an access route at least
1500mm wide
800
750
At right angles to an access route at least
1200mm wide
825
775
External doors to buildings used by the general public
1000
775

 

Specifying with doors and doorsets

related links

Configurations and handings »

Tolerances & dimensioning »