Effective clear widths
Approved Document M, Diagram, Effective clear width
Clear opening width’ is measured up to any projecting
door item including furniture, weatherboards, etc., as shown
above. A space of at least 300mm is generally required next to
the leading edge of the door to enable wheelchair users to reach
and grip the handle, unless the door is power operated. Door
opening furniture should be operable with one hand (e.g. lever
action).
.
Approved Document M, Table 2 Minimum Effective
Clear Widths
| Direction
& width of approach : |
New buildings (mm)
|
Existing buildings (mm)
|
Straight-on
(without a turn or oblique approach) |
800
|
750
|
At right angles
to an access route at least 1500mm wide |
800
|
750
|
At right angles
to an access route at least 1200mm wide |
825
|
775
|
| External doors
to buildings used by the general public |
1000
|
775
|
|